Project

General

Profile

Bug #1125

mdrun separate PME nodes timings incorrect with -resethway -maxh

Added by Berk Hess about 4 years ago. Updated about 4 years ago.

Status:
Closed
Priority:
Low
Assignee:
Category:
mdrun
Target version:
Affected version - extra info:
4.6
Affected version:
Difficulty:
uncategorized
Close

Description

The cycles, and therefore also the times, reported at the end of the log file are incorrect for separate PME nodes when counters are reset (-resethway) together with -maxh. The PME only nodes need to be signaled that they should reset their counters.

Associated revisions

Revision c18bcffe (diff)
Added by Berk Hess about 4 years ago

PME-only counters are now reset with -maxh -resethway

Fixes #1125
For clarity gmx_pme_recv_q_x now returns and enum
and gmx_pme_send_switch is renamed to gmx_pme_send_switchgrid.

Change-Id: I21952780f0b719378d947a79324c844ccde7160a

History

#1 Updated by Berk Hess about 4 years ago

  • Status changed from New to Closed

Also available in: Atom PDF