Project

General

Profile

Bug #1244

cos-acceleration viscosity output incorrect

Added by Berk Hess about 4 years ago. Updated about 4 years ago.

Status:
Closed
Priority:
Normal
Assignee:
Category:
mdrun
Target version:
Affected version - extra info:
Affected version:
Difficulty:
uncategorized
Close

Description

The viscosity output with cos-acceleration is off by a factor of the box volume.
For version 4.5.4 I ADDED a missing factor of density instead of REPLACING the volume.
Note that the incorrect viscosity value you get can be simply corrected by dividing by the box volume.

Associated revisions

Revision 25a78ecb (diff)
Added by Berk Hess about 4 years ago

fixed incorrect scaling of cos-acceleration viscosity

The cos-acceleration 1/viscosity output contained an anomalous factor
1/volume. This factor is now removed.
Fixes #1244

Change-Id: I9bf318b4e6557720683d50a0c2e887e306bacc3f

Revision 0eeab7c0 (diff)
Added by Berk Hess about 4 years ago

fixed incorrect scaling of cos-acceleration viscosity

The cos-acceleration 1/viscosity output contained an anomalous factor
1/volume. This factor is now removed.
Fixes #1244

Change-Id: I9bf318b4e6557720683d50a0c2e887e306bacc3f

History

#1 Updated by Berk Hess about 4 years ago

  • Status changed from New to Resolved
  • % Done changed from 0 to 100

#2 Updated by Mark Abraham about 4 years ago

  • Status changed from Resolved to Closed

Also available in: Atom PDF