viscosity & g_energy & acflen option is ignored

Added by Vitaly Chaban about 10 years ago. Updated over 9 years ago.

Status:
Closed
Priority:
Normal
Assignee:
Erik Lindahl
Category:
analysis tools
Target version:
Affected version - extra info:
Affected version:
Difficulty:
uncategorized
Close

Description

As calculating viscosity value with g_energy "-acflen" option is ignored. The length of the ACF is always a half the number of frames.

The command line is:
g_energy -vis -acflen XXX

The output file with ACF is enecorr.xvg.

History

#1 Updated by David van der Spoel over 9 years ago

The file made with the -vis option now has the length the user specified. However, the unasked-for evisco.xvg and eviscoi.xvg files have their standard length of nframes/4.